| UOM | EA | Weight | 13.3 lb |
| Series | Pro | Maximum Working Pressure | 5100 psi |
| Number of Machine Count Sensor Inputs | 1 | Number of Pressure and Cycle Sensor Inputs | 3 |
| Alarm Relay Resistive Maximum Operating Current | 3 A | Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
| Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W | Input Impedance | 1.1 |
| Input Response Time | 60 ms | Low Level Contact Rating | 10 W |
| Input Required Switch Type | Normally Open | Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
| Vent Valve Output Voltage | 24 VDC | Alarm Relay Inductive Minimum Permissible Load | 10 A;10m VDC |
| Pump Output with 2 Spacers | 0.12 Cubic Inch/min | Minimum cST Grade | 40 cST |
| Maximum Run Time | 30 min | Input Maximum Off Current | 1.5 mA |
| Input Voltage | 24 VDC | Alarm Relay Inductive Rated Load | 1 A |
| Overall Height | 14.5 Inch | Low Level Carry Current | 1.2 A |
| Low Level Switch Rating | 200 VDC | Low Level Switching Current | 0.5 A |
| Alarm Relay Resistive Rated Load | 2 A | Minimum Voltage | 88 VAC |
| Power Connection Type | DIN | Vent Valve Maximum Operating Current | 2 A |
| Overall Width | 9.25 Inch | Overall Depth | 10 Inch |
| Input Load Current | 22 mA @ 24 VDC | Maximum Fill Inlet Pressure | 5000 psi |
| Fluid Outlet Thread Type | NPSF | Number of Pump Elements | Up to 3 |
| Fluid Outlet Thread Gender | Female | Control Options | Pro |
| Voltage | 90-240 VAC | Maximum Voltage | 264 VAC |
| Pump Output with 0 Spacers | 0.25 Cubic Inch/min | Alarm Relay Inductive Maximum Operating Voltage | 220 VDC |
| Reservoir Size | 1.06 gal | IP Rating | IP69K |
| Vent Valve Maximum Operating Power | 48 W | Maximum NLGI Grade | #2 |
| Input Maximum Residual Voltage | 4 V | Pump Output with 1 Spacer | 0.18 Cubic Inch/min |
| Fluid Outlet Size | 0.25 Inch | Model | G3 |