| UOM | EA | Operation Type | Pilot |
| Flow Rate | 250.0 lpm, 250 lpm | For Fluid Type | Hydraulic Oil |
| Port Connection | NG25 / CETOP 08 | Connection Type | 6 + Pe |
| Material | Cast Iron | Pilot Inlet / Drain Locations | Internal / internal |
| Minimum Pilot Pressure | 30 + T/Y bar | Variation of Opening Point | set to 10 % Command Signal |
| Pilot Inlet | Internal | Technology | Hydraulics |
| Media | Hydraulic Oil | Function | 3-way |
| Leak Rate | 600.0 ml/min | Maximum Pilot Pressure | 350 bar |
| Hysteresis | < 5 % | Filter Efficiency Rating | ISO 4406; 18/16/13 |
| Application | Industrial Hydraulic | Power Supply Voltage | 18...30, Ripple < 5 % eff., Surge Free V |
| Electronics Type | Onboard | Response Time | 100 ms |
| Maximum Operating Temperature | 60 °C | IP Rating | IP65 |
| Valve Type | Proportional DC Valve | Minimum Kinematic Viscosity | 20 cSt |
| Spool Code | E02 | Maximum Ambient Temperature | 60 °C |
| Maximum Kinematic Viscosity | 400 cSt | Spool Position | Operated In Position A Or B |
| Maximum Fluid Temperature | 60 °C | Mounting Position | Unrestricted |
| Minimum Fluid Temperature | -25 °C | Minimum Ambient Temperature | -20 °C |
| Actuation Type | Proportional Solenoid | Product Series | Proportional DC Valve |
| Signal Input | 0 to ±10 V | Seal Material | NBR |
| Mounting Option | Din 24340 / ISO 4401 / Cetop Rp121 / NFPA | Valve Option | Standard |
| Minimum Operating Temperature | -20 °C | | |