- Availability & Price
- Search SKU
Filter by attributes
- Configuration
- Flow Rate
- Maximum Inlet Pressure Rating
- Override Functionality
- Seal Material
Directional Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | SKU | Availability | Partner Available | Price | UOM | Configuration | Override Functionality | Seal Material | Maximum Inlet Pressure Rating | Flow Rate | Actuation Type | Body Material | Maximum Kinematic Viscosity | Minimum Operating Temperature | Maximum Operating Pressure | Override Functionality | Coil Type | Operation Type | Power Consumption | Installation Torque | Coil Nut Tightening Torque | Cavity Size | Weight | Configuration | Filter Efficiency Rating | Frequency | For Fluid Type | Valve Material | Maximum Inlet Pressure Rating | Maximum Operating Temperature | Response Time | Maximum Tank Pressure | Function | Flow Rate | Leak Rate | Seal Material | Maximum Flow Rate | Current | Hysteresis | Flow Rate Accuracy | Variation of Opening Point |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DSP105C1 | Backordered | 6 in stock | $198.02/each | EA | Normally Closed | N/A | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -37 °C | 210 bar | n/a | 5/8" Super Coil High Watt (CAP) | Solenoid Operated | 28 W | 25 lb-ft | 3 lb-ft | C10-4 | 0.57 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 210 bar | +93 °C | 50 ms | 3000 psi | Proportional Directional Control | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | D-Ring (Standard | 32 L/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| DSP105C1M | Backordered | Backordered | $194.11/each | EA | Normally Closed | Push and Pull | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -35 °F | 210 bar | Push and Pull | 5/8" Super Coil High Watt (CAP) | Solenoid operated, Manually operated | 28 W | 25 lb-ft | 3 lb-ft | C10-4 | 0.28 kg | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 210 bar | +200 °F | 50 ms | 210 bar | Proportional Directional Control | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | D-Ring (Standard | 8.5 Gal/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| DSP105C1V | Backordered | Backordered | $167.79/each | EA | Normally Closed | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -26 °C | 3000 psi | n/a | 5/8" Super Coil High Watt (CAP) | Solenoid Operated | 28 W | 34 Nm | 3 lb-ft | C10-4 | 0.28 kg | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 210 bar | +400 °F | 50 ms | 210 bar | Proportional Directional Control | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 32 L/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| DSP105C4 | Backordered | 2 Limited Stock | $198.02/each | EA | Floating Center | N/A | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -35 °F | 210 bar | n/a | 5/8" Super Coil High Watt (CAP) | Solenoid Operated | 28 W | 25 lb-ft | 3 lb-ft | C10-4 | 0.57 lb | Floating Center | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 210 bar | +200 °F | 50 ms | 210 bar | Proportional Directional Control | 32 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | D-Ring (Standard | 32 L/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| DSP105C4M | Backordered | Backordered | $194.11/each | EA | Floating Center | Push and Pull | D-Ring (Standard) | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -35 °F | 210 bar | Push and Pull | 5/8" Super Coil High Watt (CAP) | Solenoid operated, Manually operated | 28 W | 25 lb-ft | 4.1 Nm | C10-4 | 0.57 lb | Floating Center | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 3000 psi | +200 °F | 50 ms | 210 bar | Proportional Directional Control | 8.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | D-Ring (Standard | 8.5 Gal/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| DSP105C4V | Backordered | Backordered | $167.79/each | EA | Floating Center | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8.5 GAL/MIN, 32 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -15 °F | 3000 psi | n/a | 5/8" Super Coil High Watt (CAP) | Solenoid Operated | 28 W | 34 Nm | 3 lb-ft | C10-4 | 0.28 kg | Floating Center | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 210 bar | +204 °C | 50 ms | 210 bar | Proportional Directional Control | 8.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 8.5 Gal/min | 2.33 @ 12 VDC, 1.17 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02511N | Backordered | Backordered | $224.19/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -34 °C | 5000 psi | Non-Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 4.1 Nm | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +250 °F | 50 ms | 210 bar | Proportional Directional Control | 15, 17 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 15, 17 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02512N | Backordered | Backordered | $235.71/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -30 °F | 5000 psi | Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 4.1 Nm | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +121 °C | 50 ms | 210 bar | Proportional Directional Control | 4, 4.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 4, 4.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251L1N | Backordered | Backordered | $274.48/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -30 °F | 350 bar | Non-Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 3 lb-ft | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +121 °C | 50 ms | 3000 psi | Proportional Directional Control | 0.9, 1.4 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 3.4, 5.3 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251L2N | Backordered | Backordered | $274.48/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -34 °C | 350 bar | Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 22 lb-ft | 3 lb-ft | C08-4 | 0.15 kg | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +250 °F | 50 ms | 210 bar | Proportional Directional Control | 0.9, 1.4 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 3.4, 5.3 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251LN | Backordered | Backordered | $230.30/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -30 °F | 5000 psi | n/a | 1/2" Super Coil | Solenoid Operated | 14, 19 W | 22 lb-ft | 4.1 Nm | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +121 °C | 50 ms | 3000 psi | Proportional Directional Control | 0.9, 1.4 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 0.9, 1.4 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251LV | Backordered | Backordered | $242.52/each | EA | Normally Closed | N/A | Fluorocarbon | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -26 °C | 350 bar | n/a | 1/2" Super Coil | Solenoid Operated | 14, 19 W | 22 lb-ft | 3 lb-ft | C08-4 | 0.15 kg | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +400 °F | 50 ms | 3000 psi | Proportional Directional Control | 3.4, 5.3 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 3.4, 5.3 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251N | Backordered | Backordered | $182.36/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -30 °F | 350 bar | n/a | 1/2" Super Coil | Solenoid Operated | 14, 19 W | 22 lb-ft | 4.1 Nm | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +250 °F | 50 ms | 210 bar | Proportional Directional Control | 15, 17 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 4, 4.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0251V | Backordered | Backordered | $203.51/each | EA | Normally Closed | N/A | Fluorocarbon | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -26 °C | 350 bar | n/a | 1/2" Super Coil | Solenoid Operated | 14, 19 W | 22 lb-ft | 3 lb-ft | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +400 °F | 50 ms | 3000 psi | Proportional Directional Control | 15, 17 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 4, 4.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02521N | Backordered | Backordered | $224.19/each | EA | Normally Closed | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -34 °C | 5000 psi | Non-Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 3 lb-ft | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +121 °C | 50 ms | 210 bar | Proportional Directional Control | 4.5, 5.5 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 4.5, 5.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02522N | Backordered | Backordered | $235.71/each | EA | Normally Closed | Detented | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -34 °C | 350 bar | Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 3 lb-ft | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +121 °C | 50 ms | 3000 psi | Proportional Directional Control | 17, 21 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 4.5, 5.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02522V | Backordered | Backordered | $247.22/each | EA | Normally Closed | Detented | Fluorocarbon | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -15 °F | 350 bar | Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 22 lb-ft | 3 lb-ft | C08-4 | 0.34 lb | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +400 °F | 50 ms | 210 bar | Proportional Directional Control | 17, 21 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 17, 21 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP0252N | Backordered | Backordered | $182.36/each | EA | Normally Closed | N/A | Nitrile | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | Electrical | n/a | 45-2000 SSU (6 to 420 cSt) | -34 °C | 350 bar | n/a | 1/2" Super Coil | Solenoid Operated | 14, 19 W | 22 lb-ft | 3 lb-ft | C08-4 | 0.15 kg | Normally Closed | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 350 bar | +121 °C | 50 ms | 210 bar | Proportional Directional Control | 17, 21 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 4.5, 5.5 Gal/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02531N | Backordered | Backordered | $224.19/each | EA | Floating Center | Non-Detented | Nitrile | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -30 °F | 350 bar | Non-Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 22 lb-ft | 4.1 Nm | C08-4 | 0.34 lb | Floating Center | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +250 °F | 50 ms | 3000 psi | Proportional Directional Control | 10, 15 L/min | 10 @ 3000 PSI (210 BAR) cm3/min | Nitrile | 10, 15 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | |
| GP02531V | Backordered | Backordered | $247.22/each | EA | Floating Center | Non-Detented | Fluorocarbon | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | Electrical, Manual | n/a | 45-2000 SSU (6 to 420 cSt) | -26 °C | 350 bar | Non-Detented | 1/2" Super Coil | Solenoid operated, Manually operated | 14, 19 W | 30 Nm | 3 lb-ft | C08-4 | 0.15 kg | Floating Center | ISO 4406 18/16/13, SAE Class 4 | 100-400 Hz | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 5000 psi | +400 °F | 50 ms | 3000 psi | Proportional Directional Control | 2.7, 4 Gal/min | 10 @ 3000 PSI (210 BAR) cm3/min | Fluorocarbon | 10, 15 L/min | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal |
- 1
- 2