Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMConfigurationOverride FunctionalitySeal MaterialMaximum Inlet Pressure RatingFlow RateActuation TypeBody MaterialMaximum Kinematic ViscosityMinimum Operating TemperatureMaximum Operating PressureOverride FunctionalityCoil TypeOperation TypePower ConsumptionInstallation TorqueCoil Nut Tightening TorqueCavity SizeWeightConfigurationFilter Efficiency RatingFrequencyFor Fluid TypeValve MaterialMaximum Inlet Pressure RatingMaximum Operating TemperatureResponse TimeMaximum Tank PressureFunctionFlow RateLeak RateSeal MaterialMaximum Flow RateCurrentHysteresisFlow Rate AccuracyVariation of Opening Point
DSP105C1
Backordered
6 in stock
$198.02/each
EANormally ClosedN/AD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-37 °C210 barn/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W25 lb-ft3 lb-ftC10-40.57 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel210 bar+93 °C50 ms3000 psiProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
DSP105C1M
Backordered
Backordered
$194.11/each
EANormally ClosedPush and PullD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-35 °F210 barPush and Pull5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated28 W25 lb-ft3 lb-ftC10-40.28 kgNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel210 bar+200 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
DSP105C1V
Backordered
Backordered
$167.79/each
EANormally ClosedN/AFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-26 °C3000 psin/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W34 Nm3 lb-ftC10-40.28 kgNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel210 bar+400 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
DSP105C4
Backordered
2 Limited Stock
$198.02/each
EAFloating CenterN/AD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-35 °F210 barn/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W25 lb-ft3 lb-ftC10-40.57 lbFloating CenterISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel210 bar+200 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
DSP105C4M
Backordered
Backordered
$194.11/each
EAFloating CenterPush and PullD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-35 °F210 barPush and Pull5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated28 W25 lb-ft4.1 NmC10-40.57 lbFloating CenterISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel3000 psi+200 °F50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
DSP105C4V
Backordered
Backordered
$167.79/each
EAFloating CenterN/AFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-15 °F3000 psin/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W34 Nm3 lb-ftC10-40.28 kgFloating CenterISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel210 bar+204 °C50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02511N
Backordered
Backordered
$224.19/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-34 °C5000 psiNon-Detented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm4.1 NmC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+250 °F50 ms210 barProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile15, 17 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02512N
Backordered
Backordered
$235.71/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-30 °F5000 psiDetented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm4.1 NmC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+121 °C50 ms210 barProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251L1N
Backordered
Backordered
$274.48/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-30 °F350 barNon-Detented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+121 °C50 ms3000 psiProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251L2N
Backordered
Backordered
$274.48/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-34 °C350 barDetented1/2" Super CoilSolenoid operated, Manually operated14, 19 W22 lb-ft3 lb-ftC08-40.15 kgNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+250 °F50 ms210 barProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251LN
Backordered
Backordered
$230.30/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-30 °F5000 psin/a1/2" Super CoilSolenoid Operated14, 19 W22 lb-ft4.1 NmC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+121 °C50 ms3000 psiProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile0.9, 1.4 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251LV
Backordered
Backordered
$242.52/each
EANormally ClosedN/AFluorocarbon5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-26 °C350 barn/a1/2" Super CoilSolenoid Operated14, 19 W22 lb-ft3 lb-ftC08-40.15 kgNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+400 °F50 ms3000 psiProportional Directional Control3.4, 5.3 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251N
Backordered
Backordered
$182.36/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-30 °F350 barn/a1/2" Super CoilSolenoid Operated14, 19 W22 lb-ft4.1 NmC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+250 °F50 ms210 barProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0251V
Backordered
Backordered
$203.51/each
EANormally ClosedN/AFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-26 °C350 barn/a1/2" Super CoilSolenoid Operated14, 19 W22 lb-ft3 lb-ftC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+400 °F50 ms3000 psiProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02521N
Backordered
Backordered
$224.19/each
EANormally ClosedNon-DetentedNitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-34 °C5000 psiNon-Detented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+121 °C50 ms210 barProportional Directional Control4.5, 5.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4.5, 5.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02522N
Backordered
Backordered
$235.71/each
EANormally ClosedDetentedNitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-34 °C350 barDetented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+121 °C50 ms3000 psiProportional Directional Control17, 21 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4.5, 5.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02522V
Backordered
Backordered
$247.22/each
EANormally ClosedDetentedFluorocarbon5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-15 °F350 barDetented1/2" Super CoilSolenoid operated, Manually operated14, 19 W22 lb-ft3 lb-ftC08-40.34 lbNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+400 °F50 ms210 barProportional Directional Control17, 21 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon17, 21 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP0252N
Backordered
Backordered
$182.36/each
EANormally ClosedN/ANitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MINElectricaln/a45-2000 SSU (6 to 420 cSt)-34 °C350 barn/a1/2" Super CoilSolenoid Operated14, 19 W22 lb-ft3 lb-ftC08-40.15 kgNormally ClosedISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel350 bar+121 °C50 ms210 barProportional Directional Control17, 21 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4.5, 5.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02531N
Backordered
Backordered
$224.19/each
EAFloating CenterNon-DetentedNitrile5000 PSI, 350 BAR2.7, 4 GAL/MIN, 10, 15 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-30 °F350 barNon-Detented1/2" Super CoilSolenoid operated, Manually operated14, 19 W22 lb-ft4.1 NmC08-40.34 lbFloating CenterISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+250 °F50 ms3000 psiProportional Directional Control10, 15 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile10, 15 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal
GP02531V
Backordered
Backordered
$247.22/each
EAFloating CenterNon-DetentedFluorocarbon5000 PSI, 350 BAR2.7, 4 GAL/MIN, 10, 15 L/MINElectrical, Manualn/a45-2000 SSU (6 to 420 cSt)-26 °C350 barNon-Detented1/2" Super CoilSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.15 kgFloating CenterISO 4406 18/16/13, SAE Class 4100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel5000 psi+400 °F50 ms3000 psiProportional Directional Control2.7, 4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon10, 15 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal