High Pressure Inline/Reverse Flow Filter 50P Series

Picture for category High Pressure Inline/Reverse Flow Filter 50P Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Modern high pressure hydraulic systems are demanding. Better controls and long component life are expected. To deliver the high standards of performance, hydraulic components are built with tighter tolerances increasing their sensitivity to contamination.

That's where Parker Pressure Filters come into play. Pressure filters are used to protect downstream components from contamination, protecting these critical components from catastrophic failure. They filter out ingressed contamination before it jams a valve or scores a cylinder. They block pump-generated debris before it gets to servo or proportional valves.

The design objective for all Parker filters is to achieve a sensible balance between cost and performance. Using state of the art technology to arrive at innovative yet practical designs, offers a cost effective option for both OEM's and users alike. Parker Pressure Filters are a key ingredient in meeting today's system demands.

The Parker 50P High Pressure Filter Series allows for each filter to be customized, closely matching any specific system needs. Choose the options which best fit your application. No need to waste money on features you don't need!

Design
The Parker 50P Series High Pressure Filters are base mounted, which provides several possible advantages. The bowl up mounting makes servicing the elements quick and easy. Simply remove the top cover to access the element. A drain port is provided to allow the oil to be removed from filter prior to element servicing. This design reduces the possibility of oil spillage and injury to maintenance personnel.

The Parker 50P Series has optional manifold porting for space saving design that reduces the number of fittings and potential leak points. The porting is also designed to match the installation of many other manufacturers.

Available in single, double, and triple lengths, and utilizes Microglass III media in 2, 5, 10 and 20 microns for the industry's best particle removal efficiency and retention. Most significant to note, the Parker 50P Series meets the SAE HF4 automotive standard, ensuring the safety, quality and effectiveness of products.


50PR Reverse Flow Filter
Also Available: The Parker 50PR - designed specifically for hydrostatic transmission loops because of its capability to handle reverse flow.

Closed circuit HSTs frequently reverse direction causing flow to reverse in the fluid lines. Pressure filters installed between pump and motor must be able to handle reverse flow without having contaminant washed off of the elements and back into the system. To prevent such an occurrence, the filters require the use of internal check valves to direct the flow through the element in one direction and around the element in the other. Parker's internal check valve design minimizes additional pressure loss and eliminates the cost associated with external valves and fittings. Also the internal design keeps the envelope dimensions of the filter to a minimum as can be seen on the installation drawing.


Features and Benefits
• Meets SAE HF4 Specification for Automotive Uses
• O-Ring Seal
• Positive o-ring Sealing for Optimum Element Efficiency
• Plastic End Caps
• Laser Marked for Clear Long-Lasting Identification - Excellent Corrosion Protection
• Spiral Support Cylinders
• High Strength Consistent Support
• Continuous Length Elements Eliminates Leak Points and Increases Surface Area
• Base Mounted Filter
• No brackets required for installation, reducing costs
• Top Access Cover
• Removes element from top, reducing mess
• Lighter than removing the entire bowl
• Visual and Electrical Indicators
• Know exactly when Element service is required
• Drain Port
• Drain all Oil from Assembly Prior to Servicing, Eliminates Cross-Contamination
• Vent Port
• Purges all Trapped Air in Filter, Achieving Maximum Element Performance and Prevents a “Spongy” System
• Microglass III Elements - Available in Four Different Micron Sizes
• Documented Consistent Performance, Backed by Recognized Test Standards – Providing Reliability
• Multi-Layer Media – Offering High Capacity and Efficiency
• Wire Reinforced Pleats – No Performance Loss from Pleat Bunching

Typical Applications
• Automotive specified equipment
• Hydrostatic transmission circuits
• Servo and proportional controls
• Offshore drilling rigs
• Mining equipment
• Power units
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMSeal MaterialOptionsFilter Element TypeBypass Valve Pressure RatingIndicator TypePort Connection TypeIndicator Pressure SettingFlow RateSeal MaterialFor Fluid TypeOptionsFilter Element TypeProduct StyleMounting StyleMaximum Operating TemperaturePort TypeIndicator TypeWeightFlow RateCompatible Element
50P210QML50PP1
Backordered
Backordered
POR
EANitrileNone10Q Microglass50 psi (3.4 bar)visual, left sideSAE-24 straight thread42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q MicroglassHydraulic FilterInline225.0SAE-24 straight threadvisual, left side77120.0932679Q
50P210QML50XX1
Backordered
Backordered
POR
EANitrileNone10Q Microglass50 psi (3.4 bar)visual, left side1⅜ manifold ports on bottom of filter base42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline225.0 °F1⅜ manifold ports on bottom of filter basevisual, left side34.9 kg454.0 L/min932679Q
50P210QML50YY1
Backordered
Backordered
POR
EANitrileNone10Q Microglass50 psi (3.4 bar)visual, left sideSAE 1½ code 62 flange42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline107.0 °CSAE 1½ code 62 flangevisual, left side34.9 kg454.0 L/min932679Q
50P210QML90PP1
Backordered
Backordered
POR
EANitrileNone10Q Microglass90 psi (6.2 bar)visual, left sideSAE-24 straight thread81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q MicroglassHydraulic FilterInline225.0SAE-24 straight threadvisual, left side77120.0932679Q
50P210QML90YY1
Backordered
Backordered
POR
EANitrileNone10Q Microglass90 psi (6.2 bar)visual, left sideSAE 1½ code 62 flange81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q MicroglassHydraulic FilterInline107.0 °CSAE 1½ code 62 flangevisual, left side34.9 kg454.0 L/min932679Q
50P210QP90XX1
Backordered
Backordered
POR
EANitrileNone10Q Microglass90 psi (6.2 bar)plugged ports, right side1⅜ manifold ports on bottom of filter base81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q Microglass-Inline107.0 °C1⅜ manifold ports on bottom of filter baseplugged ports, right side77 lb416.0 L/min-
50P210QPL50PP1
Backordered
Backordered
POR
EANitrileNone10Q Microglass50 psi (3.4 bar)plugged ports, left sideSAE-24 straight thread42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q MicroglassHydraulic FilterInline225.0SAE-24 straight threadplugged ports, left side77120.0932679Q
50P220QDL90PP1
Backordered
Backordered
POR
EANitrileNone20Q Microglass90 psi (6.2 bar)electrical, 3-pin male quick disconnect, left sideSAE-24 straight thread81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone20Q MicroglassHydraulic FilterInline225.0 °FSAE-24 straight threadelectrical, 3-pin male quick disconnect, left side34.9 kg454.0 L/min931020Q
50P220QHEL90YY11
Backordered
Backordered
POR
EANitrileBlocked Bypass20QH MicroglassNo Bypasselectrical indicator with wire leads and conduit connection, left sideSAE 1½ code 62 flange81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsBlocked Bypass20QH MicroglassHydraulic FilterInline225.0 °FSAE 1½ code 62 flangeelectrical indicator with wire leads and conduit connection, left side34.9 kg120.0 Gal/min931490Q
50P220QM50PP1
Backordered
Backordered
POR
EANitrileNone20Q Microglass50 psi (3.4 bar)visual, right sideSAE-24 straight thread42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone20Q MicroglassHydraulic FilterInline107.0 °CSAE-24 straight threadvisual, right side77 lb120.0 Gal/min931020Q
50P220QML50PP1
Backordered
Backordered
POR
EANitrileNone20Q Microglass50 psi (3.4 bar)visual, left sideSAE-24 straight thread42 psid (2.9 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline225.0 °FSAE-24 straight threadvisual, left side34.9 kg120.0 Gal/min931020Q
50P220QP90PP1
Backordered
Backordered
POR
EANitrileNone20Q Microglass90 psi (6.2 bar)plugged ports, right sideSAE-24 straight thread81 psid (5.6 bar)110 gpm (416 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone20Q MicroglassHydraulic FilterInline107.0 °CSAE-24 straight threadplugged ports, right side77 lb120.0 Gal/min931020Q
50P305QDL90YY1
Backordered
Backordered
POR
EANitrileNone05Q Microglass90 psi (6.2 bar)electrical, 3-pin male quick disconnect, left sideSAE 1½ code 62 flange81 psid (5.6 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone05Q MicroglassHydraulic FilterInline107.0 °CSAE 1½ code 62 flangeelectrical, 3-pin male quick disconnect, left side95 lb454.0 L/min933487Q
50P305QE35XX1
Backordered
Backordered
POR
EANitrileNone05Q Microglass35 psi (2.4 bar)electrical indicator with wire leads and conduit connection, right side1⅜ manifold ports on bottom of filter base30 psid (2.1 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline107.0 °C1⅜ manifold ports on bottom of filter baseelectrical indicator with wire leads and conduit connection, right side43 kg120.0 Gal/min933487Q
50P305QE50PP1
Backordered
Backordered
POR
EANitrileNone05Q Microglass50 psi (3.4 bar)electrical indicator with wire leads and conduit connection, right sideSAE-24 straight thread42 psid (2.9 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone05Q MicroglassHydraulic FilterInline225.0SAE-24 straight threadelectrical indicator with wire leads and conduit connection, right side95120.0933487Q
50P305QEL50XX1
Backordered
Backordered
POR
EANitrileNone05Q Microglass50 psi (3.4 bar)electrical indicator with wire leads and conduit connection, left side1⅜ manifold ports on bottom of filter base42 psid (2.9 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone05Q MicroglassHydraulic FilterInline225.01⅜ manifold ports on bottom of filter baseelectrical indicator with wire leads and conduit connection, left side95120.0933487Q
50P305QM90YY1
Backordered
Backordered
POR
EANitrileNone05Q Microglass90 psi (6.2 bar)visual, right sideSAE 1½ code 62 flange81 psid (5.6 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline225.0 °FSAE 1½ code 62 flangevisual, right side43 kg120.0 Gal/min933487Q
50P305QML90YY1
Backordered
Backordered
POR
EANitrileNone05Q Microglass90 psi (6.2 bar)visual, left sideSAE 1½ code 62 flange81 psid (5.6 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline107.0 °CSAE 1½ code 62 flangevisual, left side43 kg454.0 L/min933487Q
50P305QPL50XX1
Backordered
Backordered
POR
EANitrileNone05Q Microglass50 psi (3.4 bar)plugged ports, left side1⅜ manifold ports on bottom of filter base42 psid (2.9 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNoneCartridgeHydraulic FilterInline225.0 °F1⅜ manifold ports on bottom of filter baseplugged ports, left side95 lb454.0 L/min933487Q
50P310QD90XX1
Backordered
Backordered
POR
EANitrileNone10Q Microglass90 psi (6.2 bar)electrical, 3-pin male quick disconnect, right side1⅜ manifold ports on bottom of filter base81 psid (5.6 bar)120 gpm (454 lpm)NitrileMineral, Petroleum and Polyalphaolefin (PAO) based fluidsNone10Q MicroglassHydraulic FilterInline225.0 °F1⅜ manifold ports on bottom of filter baseelectrical, 3-pin male quick disconnect, right side95 lb120.0 Gal/min933488Q