• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Mounting Type
  • Size
More Filters...
Manufacturers

Pilot Operated Directional Control Valve - D81VW Series

Picture for category Pilot Operated Directional Control Valve - D81VW Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D81VW directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Explosion proof available
• Low pressure drop design
• Fast response option available
• Hardened spools provide long life
• No tools required for coil removal
• Wide variety of voltages and electrical connections available

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMMounting TypeMaximum Operating PressureSizeMaximum Flow RateSeal MaterialMaximum Operating PressurePower Supply VoltageMinimum Operating TemperatureMaximum Flow RateMounting TypeMaximum Operating TemperatureValve TypeConnection TypeSolenoid OptionOptionsAdditional OptionsBody MaterialWeightSizeActuation TypeSpool PositionPilot Inlet / Drain LocationsCoil Specifications MetSpool Code
D81VW002C1NJP
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500024 VDC-4160Subplate+140Pilot Operated Directional Control ValveDIN with PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C1NJW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500024 VDC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C1NTW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000240/60 - 220/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C1NYCF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C1NYCF4
Backordered
Backordered
POR
EASubplate3000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, External DrainCSA Approved002 - 4-way, 3 position; All Ports Open
D81VW002C1NYWF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C2NJW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500024 VDC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C2NYCF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C2NYW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C3NYCF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C3NYCF3A
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattPilot Choke Meter OutConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C3NYCF3D
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattStroke Adjust B EndConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredExternal Pilot, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C5NKW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500012 VDC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C5NYCF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6NJC3A
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500024 VDC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxOmit - High WattPilot Choke Meter OutConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6NJW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile500024 VDC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6NYCF
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6NYCF3A
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxLow WattPilot Choke Meter OutConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, Internal DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6NYW
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMNitrile5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveDIN w/o PlugOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open
D81VW002C6VYC
Backordered
Backordered
POR
EASubplate5000 PSINFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot160 GPMFluorocarbon5000120/60 - 110/50 VAC-4160Subplate+140Pilot Operated Directional Control ValveLeadwire Conduit BoxOmit - High WattOmit - No OptionsConsult catalog for other available featuresGrey Iron43.2NFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotHydaulic PressureDouble solenoid, 3 position, spring centeredInternal Pilot w/Check, External DrainOmit - Standard Valve002 - 4-way, 3 position; All Ports Open