PRH082K30 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU PRH082K30
$95.70/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAAdjustment MechanismKnob
Flow Rate8 GAL/MIN, 30 L/MINSeal MaterialD-Ring (Standard)
Pressure Control Range200-3000 PSI, 13.8-210 BARBody Materialn/a
Maximum Operating Pressure5000 psiMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-37 °CMaximum Flow Rate30 L/min
Flow Rate30 L/minActuation TypePressure Sensing
Maximum Pressure Setting210 barOperation TypeAutomatic
Adjustment MechanismKnobFunctionPilot Operated
Maximum Tank Pressure350 barSeal MaterialD-Ring (Standard)
Cavity SizeC08-3Weight0.25 lb
Maximum Inlet Pressure Rating380 barInstallation Torque43-49 Nm
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Mounting TypeScrew in cartridge valveMaximum Operating Temperature+93 °C
Valve MaterialAll parts steel. All operating parts hardened steel.Standard Setting Pressure1500 psi
ConfigurationPressure ReducingPressure Control Range200-3000 psi
Maximum Drain Flow Rate0.15 Gal/minPressure Control Sensitivity942 per turn psi
Product resources