Pilot Operated Pressure Reducing Valves - PRH082K50

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Backordered
SKU PRH082K50
$95.70
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAAdjustment MechanismKnob
Flow Rate8 GAL/MIN, 30 L/MINSeal MaterialD-Ring (Standard)
Pressure Control Range200-5000 PSI, 13.8-350 BARBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-35 °F
Maximum Operating Pressure350 barFlow Rate30 L/min
Maximum Flow Rate8 Gal/minActuation TypePressure Sensing
Weight0.11 kgOperation TypeAutomatic
Adjustment MechanismKnobFunctionPilot Operated
Maximum Tank Pressure350 barSeal MaterialD-Ring (Standard)
Cavity SizeC08-3Maximum Inlet Pressure Rating5500 psi
Installation Torque43-49 NmFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsMounting TypeScrew in cartridge valve
Maximum Operating Temperature+93 °COperating Temperature-35 to +200 °F
Valve MaterialAll parts steel. All operating parts hardened steel.Standard Setting Pressure172.4 bar
Maximum Pressure Setting350 barConfigurationPressure Reducing
Pressure Control Range13.8-350 barMaximum Drain Flow Rate0.56 L/min
Pressure Control Sensitivity137.6 per turn bar
Product resources