PRH082K50V - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU PRH082K50V
$101.14/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialFluorocarbon
Adjustment MechanismKnobFlow Rate8 GAL/MIN, 30 L/MIN
Pressure Control Range200-5000 PSI, 13.8-350 BARSeal MaterialFluorocarbon
Body Materialn/aMaximum Operating Pressure5000 psi
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-26 °C
Maximum Flow Rate8 Gal/minActuation TypePressure Sensing
Operation TypeAutomaticAdjustment MechanismKnob
FunctionPilot OperatedFlow Rate8 Gal/min
Maximum Tank Pressure5000 psiMaximum Pressure Setting5000 psi
Cavity SizeC08-3Weight0.25 lb
Maximum Inlet Pressure Rating380 barMaximum Operating Temperature+204 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Mounting TypeScrew in cartridge valveInstallation Torque32-36 lb-ft
Valve MaterialAll parts steel. All operating parts hardened steel.Standard Setting Pressure172.4 bar
ConfigurationPressure ReducingPressure Control Range13.8-350 bar
Maximum Drain Flow Rate0.56 L/minPressure Control Sensitivity137.6 per turn bar
Product resources