Pilot Operated Sequence Valves - SVH102S50V

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Backordered
SKU SVH102S50V
$85.26
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialFluorocarbon
Adjustment TypeScrewRated Flow (gpm)15
Cracking Pressure (psi)N/APressure Range Adjustment (psi)200-5000
Drain OptionInternalPilot OptionExternal
Port Sizen/aSeal MaterialFluorocarbon
Body Materialn/aMaximum Operating Pressure5500 psi
Flow Rate15 Gal/minDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationExternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-26 °C
Actuation TypePressure SensingAdjustment MechanismScrew
Maximum Tank Pressure350 barDrain OptionInternal
Cavity SizeC10-3FunctionPilot Operated Sequence
Weight0.45 kgMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating380 barMaximum Operating Temperature+400 °F
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-26 to +204 °C
Installation Torque69-75 NmMaximum Flow Rate56.3 L/min
Maximum Pressure Setting350 barStandard Setting Pressure2500 psi
Pressure Control Sensitivity131.7 per turn barCracking PressureN/A psi
Pressure Control Range13.8-350 barLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureMaximum Drain Flow Rate1.87 Gal/min