Pressure Compensated Priority Flow Control Valves - FP101F200

Pressure compensated priority flow control valves maintain constant flow regardless of changes to inlet pressure for flows up to 90 lpm (24 gpm) and pressures up to 420 bar (6000 psi); excess flow is diverted once the priority flow requirement is met.
Availability:
Backordered
SKU FP101F200
$117.67
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Adjustment MechanismFixedMaximum Flow Rate15 GAL/MIN, 56.3 L/MIN
Flow Rate Display RangeN/AStandard Flow Rate Setting2 GAL/MIN, 7.5 L/MIN
Seal MaterialNitrileConnection Sizen/a
Connection Typen/aBody Materialn/a
Flow Rate15 Gal/minDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Flow Rate15 Gal/min
Installation Torque22 NmMaximum Operating Pressure3500 psi
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Weight0.23 kg
Minimum Operating Temperature-34 °COperation TypeAutomatic
Cavity SizeC10-3Adjustment MechanismFixed
Maximum Operating Temperature+250 °FFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-30 to +250 °FActuation TypePressure Compensated
Maximum Inlet Pressure Rating245 barConfigurationPriority Flow
FunctionFlow Regulator ValveFlow Rate Accuracy20%
Maximum Priority Flow30 L/minFlow Rate Display RangeN/A L/min
Standard Flow Rate Setting2 Gal/minMaximum Regulated Flow RateN/A L/min
Product resources