Standard Pilot Assisted Load Control Valves - MHC-010-SFNK-00F

Parker’s piloted load control valves are designed to operate independent of downstream pressure to prevent runaway loads under dynamic conditions using a pilot signal, handling pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm).
Availability:
Backordered
SKU MHC-010-SFNK-00F
$128.32
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialFluorocarbon
Port Sizen/aMounting TypeThreaded Cartridge Valve
Pilot Pressure Ratio7:1Maximum Flow Rate10 GAL/MIN, 37.5 L/MIN
Holding Pressure5000 PSI, 350 BARAdjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/AActuation TypePilot Operated
Port Sizen/aSeal MaterialFluorocarbon
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationExternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-15 °F
Maximum Operating Pressure350 barMaximum Inlet Pressure Rating350 bar
Maximum Flow Rate10 Gal/minFunctionCounterbalance Valve
Mounting TypeThreaded Cartridge ValvePilot Pressure Ratio7:1
Maximum Operating Temperature+204 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-15 to +400 °FFlow Rate37.5 L/min
Weight0.38 kgLeak Rate5 @ 80% of setting drops/min
Pressure Control SensitivityN/A barCavity SizeCDD-1010
Flow DirectionCylinder port 2, Valve port 3, Pilot port 1Holding Pressure5000 psi
Installation Torque68-75 NmAdjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/A bar
Product resources