*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s piloted load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open based off a given backpressure specific to the application, which could be much lower than the spring pressure setting. This feature allows predictable and consistent control of a load throughout its lowering cycle.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
Read More...Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
| Action | SKU | Availability | Partner Available | Price | UOM | Seal Material | Port Size | Mounting Type | Pilot Pressure Ratio | Adjustment Mechanism | Pressure Control Range | Holding Pressure | Maximum Flow Rate | Seal Material | Actuation Type | Port Size | Body Material | Pilot Location | Maximum Kinematic Viscosity | Minimum Operating Temperature | Maximum Operating Pressure | Flow Rate | Maximum Flow Rate | Maximum Inlet Pressure Rating | Function | Mounting Type | Maximum Operating Temperature | Filter Efficiency Rating | For Fluid Type | Valve Material | Weight | Leak Rate | Pilot Pressure Ratio | Pressure Control Sensitivity | Flow Direction | Adjustment Mechanism | Pressure Control Range | Cavity Size | Holding Pressure | Installation Torque |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MHC-022-SJSJ-00B | Backordered | Backordered | $344.09/each | EA | Nitrile | n/a | Threaded Cartridge Valve | 10:1 | Standard (adjustable) | N/A | 3500 PSI, 240 BAR | 25 GAL/MIN, 93.75 L/MIN | Nitrile | Pilot Operated | n/a | n/a | External | 45-2000 SSU (6 to 420 cSt) | -30 °F | 350 bar | 25 Gal/min | 25 Gal/min | 350 bar | Counterbalance Valve | Threaded Cartridge Valve | +121 °C | ISO 4406 18/16/13, SAE Class 4 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 0.38 kg | 5 @ 80% of setting drops/min | 10:1 | N/A bar | Cylinder port 2, Valve port 3, Pilot port 1 | Standard (adjustable) | N/A psi | CDD-1036 | 240 bar | 102-108 Nm | |
| MHC-022-SJSK-00B | Backordered | Backordered | $235.99/each | EA | Nitrile | n/a | Threaded Cartridge Valve | 10:1 | Standard (adjustable) | N/A | 5000 PSI, 350 BAR | 25 GAL/MIN, 93.75 L/MIN | Nitrile | Pilot Operated | n/a | n/a | External | 45-2000 SSU (6 to 420 cSt) | -30 °F | 350 bar | 93.75 L/min | 93.75 L/min | 5000 psi | Counterbalance Valve | Threaded Cartridge Valve | +250 °F | ISO 4406 18/16/13, SAE Class 4 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | 0.38 kg | 5 @ 80% of setting drops/min | 10:1 | N/A bar | Cylinder port 2, Valve port 3, Pilot port 1 | Standard (adjustable) | N/A psi | CDD-1036 | 5000 psi | 75-80 lb-ft |