MHC-010-VASC-00B - Standard Pilot Vented Load Control Valves

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
Availability:
Backordered
Estimated Lead Time: 176 days
Partner Available:1 Limited Stock
SKU MHC-010-VASC-00B
$333.56/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Port Sizen/aMounting TypeThreaded Cartridge Valve
Maximum Flow Rate10 GAL/MIN, 37.5 L/MINHolding Pressure500 PSI, 34.5 BAR
Pilot Pressure Ratio1:1Adjustment MechanismStandard (adjustable)
Pressure Control RangeN/ASeal MaterialNitrile
Port Sizen/aBody Materialn/a
Pilot LocationExternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-30 °FMaximum Operating Pressure350 bar
Maximum Inlet Pressure Rating350 barFlow Rate10 Gal/min
Maximum Flow Rate10 Gal/minFunctionCounterbalance Valve
Mounting TypeThreaded Cartridge ValveMaximum Operating Temperature+121 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelActuation TypePilot Operated, Vented
Weight0.38 kgPilot Pressure Ratio1:1
Leak Rate5 @ 80% of setting drops/minPressure Control SensitivityN/A psi
Cavity SizeCDD-1010Flow DirectionCylinder port 2, Valve port 3, Pilot port 1
Holding Pressure500 psiInstallation Torque68-75 Nm
Adjustment MechanismStandard (adjustable)Pressure Control RangeN/A psi
Product resources