Standard Pilot Vented Load Control Valves - MHC-010-VJNH-00B

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
Availability:
Backordered
SKU MHC-010-VJNH-00B
$259.04
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Port Sizen/aMounting TypeThreaded Cartridge Valve
Holding Pressure3000 PSI, 210 BARMaximum Flow Rate10 GAL/MIN, 37.5 L/MIN
Pilot Pressure Ratio10:1Adjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/ASeal MaterialNitrile
Port Sizen/aBody Materialn/a
Maximum Operating Pressure5000 psiDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationExternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-30 °F
Maximum Inlet Pressure Rating350 barFunctionCounterbalance Valve
Mounting TypeThreaded Cartridge ValveHolding Pressure210 bar
Maximum Operating Temperature+121 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-30 to +250 °FActuation TypePilot Operated, Vented
Flow Rate37.5 L/minMaximum Flow Rate37.5 L/min
Weight0.38 kgLeak Rate5 @ 80% of setting drops/min
Pilot Pressure Ratio10:1Pressure Control SensitivityN/A bar
Cavity SizeCDD-1010Flow DirectionCylinder port 2, Valve port 3, Pilot port 1
Installation Torque50-55 lb-ftAdjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/A psi
Product resources