- Availability & Price
- Search SKU
Filter by attributes
- Fitting Thread Size
- Flange Size
- Hose I.D. (inch)
- Length
- Notes
- Product Style
Subsea Fittings (Series E3 and E4)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s E3/E4 Series offer improved system performance, simplified hose routing and eliminates the need for adaptors. These fittings are specifically designed for the rigors of subsea use and exceed the performance requirements of API-17E and ISO 13628-5. They are hermetically sealed with an industry exclusive, patent-pending O-ring boss design for unmatched protection against moisture ingression. PATENT PENDING
Markets:
• Oil & Gas
Features/Benefits:
• Available for 1/4”, 1/2” and 1” hose sizes and in straight, 45° and 90° configurations
• JIC and Dual Seal Flange (Sub Seal) connections available
• Parker’s Dual Seal Flange Fittings use both a radial seal and face seal to achieve superior leak-free port connections and utilize SAE Code 62 flange dimensions so standard SAE mounting clamps and hardware can be used
• 5,000 psi (34 MPa) with 4:1 design factor
• 316/316L stainless steel construction for superior corrosion resistance
• Heat Lot Code traceable
Applications:
• BOP stack hydraulic lines
Note:
• Assembly working pressure is dependent on the lowest rated component. Therefore, if the hose has a lower pressure rating
than the fitting, the working pressure of the fitting is the working pressure of the assembly.
Read More...Markets:
• Oil & Gas
Features/Benefits:
• Available for 1/4”, 1/2” and 1” hose sizes and in straight, 45° and 90° configurations
• JIC and Dual Seal Flange (Sub Seal) connections available
• Parker’s Dual Seal Flange Fittings use both a radial seal and face seal to achieve superior leak-free port connections and utilize SAE Code 62 flange dimensions so standard SAE mounting clamps and hardware can be used
• 5,000 psi (34 MPa) with 4:1 design factor
• 316/316L stainless steel construction for superior corrosion resistance
• Heat Lot Code traceable
Applications:
• BOP stack hydraulic lines
Note:
• Assembly working pressure is dependent on the lowest rated component. Therefore, if the hose has a lower pressure rating
than the fitting, the working pressure of the fitting is the working pressure of the assembly.
Subsea Fittings (Series E3 and E4) - 106E3-4-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 106E3-6-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 106E3-8-8C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 106E4-16-16C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
$661.96
Subsea Fittings (Series E3 and E4) - 137E3-16-16C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 137E3-4-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 137E3-6-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 137E3-8-8C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 137E4-16-16C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 139E3-16-16C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 139E3-4-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 139E3-6-4C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 139E3-8-8C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 139E4-16-16C-411
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19GE3-16-8C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19GE3-8-8C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19GE4-16-16C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19GE4-24-16C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19ME3-16-16C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
Subsea Fittings (Series E3 and E4) - 19ME3-24-16C
Parker's E3/E4 fittings are designed to be used with 2390N High Pressure Subsea hose. These fittings eliminate the need for adaptors and provide the highest level of resistance to moisture ingression.
POR
- 1
- 2