800 Series Platinum Resistance Temperature Transmitters
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
- Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
- Economical price
- Wide variety of temperature ranges and connections
| Action | SKU | Availability | Partner Available | Price | UOM | Note | Application | Prop 65 Warnings | Additional Information | Limitations Which Apply Are | Warranty_yr | Related Items | Process Connection Size | Accuracy | Measuring Element | Options and Accessories | Output Signal | Electrical Protection | Electromagnetic Rating | Thermowells | Output | Load Limitations | Power Supply | Sensor Protection | Environmental Protection | Storage Temperature [Min]_ºC | Storage Temperature [Min]_ºF | Standard Temperature Ranges_ºF | Type | Pressure Rating_psi | Ambient Temperature Range_ºC | Operating Temperature [Min]_ºF | Stem Lengths_in | Series | Approximate Weight_oz | Electrical Connection | Housing Material | Temperature [Max]_ºF | Storage Temperature [Max]_ºF | Sensor Length_in | Temperature [Min]_ºF | Wetted Materials | Storage Temperature [Max]_ºC | Connection Size_in | Operating Temperature [Max]_ºF | Stem Diameter_mm | Ambient Temperature Range_ºF | Process Connection Type | Process Connection |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 800-0/200-1-1-8-8-025-6 | Backordered | Backordered | $347.52/each | EA | Thermowells are recommended for pressure, corrosive fluids and high velocity applications. |
| WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. | 3 | 50-025-304-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 50-025-316-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell 75-025-304-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-025-316-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell | 1/2 | Class B + (±0.5 % BFSL) | Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751)) | NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection. | 4 to 20 mA, 2-Wire | Reverse polarity, over-voltage and short circuit protection | Built to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. | ±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale | ≤(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>≤5000 Ω for 1 to 5 Vdc output<br>≤10, 000 Ω for 0 to 10 Vdc output<br>≤4500 Ω for 0.5 to 4.5 Vdc output | 10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire) | Burnout Protected from 3.3 to 23 mA | Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529)) | -40 | -40 | -40 to 120 50 to 400 | Transmitter | 725 | -40 to 85 | 0 | 2.5 | 800 | 4 | DIN EN 175301-803 Form A | 316 Stainless Steel | 200 | 185 | 2.5 | 0 | 316 Stainless Steel | 85 | 1/2 in | 200 | 6 | -40 to 185 | NPT Male | 1/2" NPT Male | |
| 800-0/200-1-5-8-8-025-6 | Backordered | Backordered | $364.58/each | EA | Thermowells are recommended for pressure, corrosive fluids and high velocity applications. |
| WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. | 3 | 50-025-304-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 50-025-316-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell 75-025-304-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-025-316-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell | 1/2 | Class B + (±0.5 % BFSL) | Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751)) | NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection. | 0 to 10 Vdc, 3-Wire | Reverse polarity, over-voltage and short circuit protection | Built to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. | ±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale | ≤(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>≤5000 Ω for 1 to 5 Vdc output<br>≤10, 000 Ω for 0 to 10 Vdc output<br>≤4500 Ω for 0.5 to 4.5 Vdc output | 10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire) | Burnout Protected from 3.3 to 23 mA | Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529)) | -40 | -40 | -40 to 120 50 to 400 | Transmitter | 725 | -40 to 85 | 0 | 2.5 | 800 | 4 | DIN EN 175301-803 Form A | 316 Stainless Steel | 200 | 185 | 2.5 | 0 | 316 Stainless Steel | 85 | 1/2 in | 200 | 6 | -40 to 185 | NPT Male | 1/2" NPT Male | |
| 800-20/240-1-5-8-8-090-6 | Backordered | Backordered | $378.22/each | EA | Thermowells are recommended for pressure, corrosive fluids and high velocity applications. |
| WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. | 3 | 50-090-304-SS, 1/2" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-090-304-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-090-316-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell | 1/2 | Class B + (±0.5 % BFSL) | Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751)) | NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection. | 0 to 10 Vdc, 3-Wire | Reverse polarity, over-voltage and short circuit protection | Built to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. | ±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale | ≤(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>≤5000 Ω for 1 to 5 Vdc output<br>≤10, 000 Ω for 0 to 10 Vdc output<br>≤4500 Ω for 0.5 to 4.5 Vdc output | 10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire) | Burnout Protected from 3.3 to 23 mA | Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529)) | -40 | -40 | -40 to 120 50 to 400 | Transmitter | 725 | -40 to 85 | 20 | 9 | 800 | 4 | DIN EN 175301-803 Form A | 316 Stainless Steel | 240 | 185 | 9 | 20 | 316 Stainless Steel | 85 | 1/2 in | 240 | 6 | -40 to 185 | NPT Male | 1/2" NPT Male |
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to