• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature Range_ºC
  • Ambient Temperature Range_ºF
  • Approximate Weight_oz
  • Connection Size_in
  • Electrical Connection
  • Housing Material
  • Operating Temperature [Max]_ºF
  • Operating Temperature [Min]_ºF
  • Pressure Rating_psi
  • Process Connection
More Filters...
Filter by manufacturer
Manufacturers

800 Series Platinum Resistance Temperature Transmitters

Picture for category 800 Series Platinum Resistance Temperature Transmitters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

  • Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
  • Economical price
  • Wide variety of temperature ranges and connections
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMNoteApplicationProp 65 WarningsAdditional InformationLimitations Which Apply AreWarranty_yrRelated ItemsProcess Connection SizeAccuracyMeasuring ElementOptions and AccessoriesOutput SignalElectrical ProtectionElectromagnetic RatingThermowellsOutputLoad LimitationsPower SupplySensor ProtectionEnvironmental ProtectionStorage Temperature [Min]_ºCStorage Temperature [Min]_ºFStandard Temperature Ranges_ºFTypePressure Rating_psiAmbient Temperature Range_ºCOperating Temperature [Min]_ºFStem Lengths_inSeriesApproximate Weight_ozElectrical ConnectionHousing MaterialTemperature [Max]_ºFStorage Temperature [Max]_ºFSensor Length_inTemperature [Min]_ºFWetted MaterialsStorage Temperature [Max]_ºCConnection Size_inOperating Temperature [Max]_ºFStem Diameter_mmAmbient Temperature Range_ºFProcess Connection TypeProcess Connection
800-0/200-1-1-8-8-025-6
Backordered
Backordered
$347.52/each
EAThermowells are recommended for pressure, corrosive fluids and high velocity applications.
  • Water systems
  • Storage tanks
  • Industrial machinery and machine tools
  • HVAC systems
  • Refrigeration systems
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Quick response time
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • Built to suppress RFI, EMI, and ESD
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
350-025-304-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 50-025-316-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell 75-025-304-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-025-316-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell1/2Class B + (±0.5 % BFSL)Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.4 to 20 mA, 2-WireReverse polarity, over-voltage and short circuit protectionBuilt to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) ProtectionThermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale&le;(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>&le;5000 &Omega; for 1 to 5 Vdc output<br>&le;10, 000 &Omega; for 0 to 10 Vdc output<br>&le;4500 &Omega; for 0.5 to 4.5 Vdc output10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire)Burnout Protected from 3.3 to 23 mAIngress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529))-40-40-40 to 120 50 to 400Transmitter725-40 to 8502.58004DIN EN 175301-803 Form A316 Stainless Steel2001852.50316 Stainless Steel851/2 in2006-40 to 185NPT Male1/2" NPT Male
800-0/200-1-5-8-8-025-6
Backordered
Backordered
$364.58/each
EAThermowells are recommended for pressure, corrosive fluids and high velocity applications.
  • Water systems
  • Storage tanks
  • Industrial machinery and machine tools
  • HVAC systems
  • Refrigeration systems
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Quick response time
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • Built to suppress RFI, EMI, and ESD
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
350-025-304-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 50-025-316-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell 75-025-304-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-025-316-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell1/2Class B + (±0.5 % BFSL)Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.0 to 10 Vdc, 3-WireReverse polarity, over-voltage and short circuit protectionBuilt to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) ProtectionThermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale&le;(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>&le;5000 &Omega; for 1 to 5 Vdc output<br>&le;10, 000 &Omega; for 0 to 10 Vdc output<br>&le;4500 &Omega; for 0.5 to 4.5 Vdc output10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire)Burnout Protected from 3.3 to 23 mAIngress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529))-40-40-40 to 120 50 to 400Transmitter725-40 to 8502.58004DIN EN 175301-803 Form A316 Stainless Steel2001852.50316 Stainless Steel851/2 in2006-40 to 185NPT Male1/2" NPT Male
800-20/240-1-5-8-8-090-6
Backordered
Backordered
$378.22/each
EAThermowells are recommended for pressure, corrosive fluids and high velocity applications.
  • Water systems
  • Storage tanks
  • Industrial machinery and machine tools
  • HVAC systems
  • Refrigeration systems
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Quick response time
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • Built to suppress RFI, EMI, and ESD
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
350-090-304-SS, 1/2" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-090-304-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-090-316-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell1/2Class B + (±0.5 % BFSL)Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.0 to 10 Vdc, 3-WireReverse polarity, over-voltage and short circuit protectionBuilt to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) ProtectionThermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.±[0.30 + 0.005 ltl] ºC<br>±0.5% Full Scale&le;(VPower - 10)/0.020 Amp for 4 to 20 mA output<br>&le;5000 &Omega; for 1 to 5 Vdc output<br>&le;10, 000 &Omega; for 0 to 10 Vdc output<br>&le;4500 &Omega; for 0.5 to 4.5 Vdc output10 to 30 Vdc (4 to 20 mA, 2-Wire)<br>10 to 30 Vdc (0 to 5 Vdc, 3-Wire)<br>10 to 30 Vdc (1 to 5 Vdc, 3-Wire)<br>14 to 30 Vdc (0 to 10 Vdc, 3-Wire)Burnout Protected from 3.3 to 23 mAIngress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529))-40-40-40 to 120 50 to 400Transmitter725-40 to 852098004DIN EN 175301-803 Form A316 Stainless Steel240185920316 Stainless Steel851/2 in2406-40 to 185NPT Male1/2" NPT Male