| UOM | EA | Pilot Inlet | Pilot Line Body: External from X (A-X closed / B-Y open) |
| Minimum Opening Pressure | A-B 0.3 bar | Maximum Flow Rate | 360 lpm |
| Pilot Inlet / Drain Locations | Pilot line body: External from X (A-X closed / B-Y open) | For Fluid Type | Water Glycol |
| Material | Cast Iron | Port Connection | NG25 / ISO 6264 |
| Function | Vent Function Solenoid Activated, Unpressurized Circulation, with Manual Override. | Sleeve Type | AA=0.95 AC, AB=0.05 AC |
| Seal Material | FPM | Minimum Operating Temperature | -20 °C |
| Mounting Option | Subplate | Switching Option | Vent Function: Solenoid Activated, Unpressurized Circulation, with Manual Override |
| Actuation Type | Pilot | Maximum Operating Temperature | 60 °C |
| Mounting Position | Unrestricted | Spool Type | Poppet with Closed Bottom, 45° Chamfer |
| Product Series | Check Valve | Cover | Pilot line Cap: With Vent Function, Internal Pilot Drain, X Open, Y Open, Z Orifice 1.2, X-Y Closed, Y1 Closed, VV01 Open |