D81VW002C6VYEU - Pilot Operated Directional Control Valve - D81VW Series

Parker’s D81VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves.
Availability:
Backordered
Estimated Lead Time: 112 days
Partner Available:Backordered
SKU D81VW002C6VYEU
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAMounting TypeSubplate
Maximum Operating Pressure5000 PSISizeNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
Maximum Flow Rate160 GPMSeal MaterialFluorocarbon
Maximum Operating Pressure5000Minimum Operating Temperature-4
Maximum Flow Rate160Mounting TypeSubplate
Maximum Operating Temperature+140Valve TypePilot Operated Directional Control Valve
Power Supply Voltage120/60 - 110/50 VACConnection TypeExplosion Proof
OptionsOmit - No OptionsAdditional OptionsConsult catalog for other available features
Body MaterialGrey IronWeight43.2
SizeNFPA D08, CETOP8, DIN NG25, Low Flow, D03 PilotActuation TypeHydaulic Pressure
Spool PositionDouble solenoid, 3 position, spring centeredCoil Specifications MetOmit - Standard Valve
Solenoid OptionExplosion Proof, UL/CSAPilot Inlet / Drain LocationsInternal Pilot w/Check, Internal Drain
Spool Code002 - 4-way, 3 position; All Ports Open