2 Way Poppet Type Solenoid Valve

Picture for category 2 Way Poppet Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMConfigurationMaximum Inlet Pressure RatingSeal MaterialActuation TypeFlow RateWire Mesh Screen IncludedMaximum Inlet Pressure RatingFunctionResponse TimeMaximum Operating TemperatureFlow DirectionBody MaterialInstallation TorqueSeal MaterialCoil TypeMinimum Operating TemperatureInput VoltageMaximum Operating PressureLeak RateValve MaterialMaximum Kinematic ViscosityFlow RateFilter Efficiency RatingAdjustment MechanismMaximum Flow RateActuation TypeCoil Nut Tightening TorqueConfigurationOverride FunctionalityCavity SizeMounting TypeFree Reverse FlowFor Fluid TypeOperation TypeWeightWire Mesh Screen Included
DSH081C
2 Limited Stock
12 in stock
$59.60/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINNo5000 psi2-Way50 ms+200 °FSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-37 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical5-7 lb-ftNormally Closedn/aC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbNo
DSH081CH
Backordered
Backordered
$77.65/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINNo350 bar2-Way30 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35.0 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical5-7 lb-ftNormally Closedn/aC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid Operated0.11 kgNo
DSH081CHR
Backordered
Backordered
$81.56/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINNo350 bar2-Way30 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35.0 °F85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical7-10 NmNormally Closedn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.11 kgNo
DSH081CHRT
Backordered
Backordered
$122.02/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo350 bar2-Way30 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35.0 °F85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical, Manual7-10 NmNormally ClosedPush and TwistC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.11 kgNo
DSH081CHRTV
Backordered
Backordered
$127.02/each
EANormally Closed5000 PSI, 350 BARFluorocarbonElectrical, Manual8 GAL/MIN, 30 L/MINNo5000 psi2-Way30 ms+400 °FSide to Nose (2-1)n/a32-36 lb-ftFluorocarbon1/2" Super Coil-26 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical, Manual5-7 lb-ftNormally ClosedPush and TwistC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbNo
DSH081CHRV
Backordered
Backordered
$85.91/each
EANormally Closed5000 PSI, 350 BARFluorocarbonElectrical8 GAL/MIN, 30 L/MINNo5000 psi2-Way30 ms+400 °FSide to Nose (2-1)n/a32-36 lb-ftFluorocarbon1/2" Super Coil-15 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical5-7 lb-ftNormally Closedn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbNo
DSH081CHT
Backordered
Backordered
$118.32/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo5000 psi2-Way30 ms+93 °CSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-37 °C85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical, Manual7-10 NmNormally ClosedPush and TwistC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbNo
DSH081CR
4 in stock
20 in stock
$62.21/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINNo5000 psi2-Way50 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35.0 °F85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical7-10 NmNormally Closedn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.11 kgNo
DSH081CRS
Backordered
Backordered
$71.12/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINYes5000 psi2-Way50 ms+200 °FSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-37 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical5-7 lb-ftNormally Closedn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbYes
DSH081CRT
Backordered
7 in stock
$140.66/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35.0 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical, Manual5-7 lb-ftNormally ClosedPush and TwistC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.11 kgNo
DSH081CRTS
Backordered
Backordered
$112.01/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINYes5000 psi2-Way50 ms+93 °CSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-37 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical, Manual5-7 lb-ftNormally ClosedPush and TwistC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbYes
DSH081CRV
Backordered
Backordered
$69.38/each
EANormally Closed5000 PSI, 350 BARFluorocarbonElectrical8 GAL/MIN, 30 L/MINNo5000 psi2-Way50 ms+400 °FSide to Nose (2-1)n/a32-36 lb-ftFluorocarbon1/2" Super Coil-26 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical5-7 lb-ftNormally Closedn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.11 kgNo
DSH081CS
Backordered
Backordered
$68.73/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINYes350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical7-10 NmNormally Closedn/aC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbYes
DSH081CT
Backordered
Backordered
$98.31/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-37 °C85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical, Manual5-7 lb-ftNormally ClosedPush and TwistC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbNo
DSH081CTS
Backordered
Backordered
$109.19/each
EANormally Closed5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINYes350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical, Manual5-7 lb-ftNormally ClosedPush and TwistC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbYes
DSH081CV
Backordered
Backordered
$66.99/each
EANormally Closed5000 PSI, 350 BARFluorocarbonElectrical8 GAL/MIN, 30 L/MINNo5000 psi2-Way50 ms+400 °FSide to Nose (2-1)n/a43-49 NmFluorocarbon1/2" Super Coil-26 °C85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical7-10 NmNormally Closedn/aC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid Operated0.11 kgNo
DSH081N
Backordered
Backordered
$83.74/each
EANormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical8 GAL/MIN, 30 L/MINNo350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical5-7 lb-ftNormally Openn/aC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbNo
DSH081NE
Backordered
Backordered
$99.18/each
EANormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo350 bar2-Way50 ms+200 °FSide to Nose (2-1)n/a43-49 NmD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)8 Gal/minISO 4406 18/16/13, SAE Class 4N/A30 L/minElectrical, Manual5-7 lb-ftNormally OpenPush Type w/Extended RodC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.11 kgNo
DSH081NM
Backordered
Backordered
$99.18/each
EANormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, Manual8 GAL/MIN, 30 L/MINNo5000 psi2-Way50 ms+200 °FSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min5000 psi5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical, Manual5-7 lb-ftNormally OpenPush Type w/Flush RodC08-2Screw in cartridge valveNoMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operated0.25 lbNo
DSH081NR
59 in stock
26 in stock
$86.13/each
EANormally Open5000 PSI, 350 BARNitrileElectrical8 GAL/MIN, 30 L/MINNo350 bar2-Way50 ms+93 °CSide to Nose (2-1)n/a32-36 lb-ftD-Ring (Standard)1/2" Super Coil-35 °F85% of rated voltage at 72°F (20°C) min350 bar5 drops/minAll parts steel. All operating parts hardened steel45-2000 SSU (6 to 420 cSt)30 L/minISO 4406 18/16/13, SAE Class 4N/A8 Gal/minElectrical7-10 NmNormally Openn/aC08-2Screw in cartridge valveYesMineral-based or synthetic hydraulic fluidsSolenoid Operated0.25 lbNo