• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
  • Wire Mesh Screen Included
More Filters...
Manufacturers

2 Way Poppet Type Solenoid Valve

Picture for category 2 Way Poppet Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMConfigurationFlow RateMaximum Inlet Pressure RatingSeal MaterialActuation TypeWire Mesh Screen IncludedBody MaterialMaximum Operating PressureFlow DirectionMaximum Kinematic ViscosityMinimum Operating TemperatureFunctionMaximum Operating TemperatureMaximum Flow RateFlow RateCavity SizeMaximum Inlet Pressure RatingSeal MaterialWeightInstallation TorqueConfigurationActuation TypeFilter Efficiency RatingFor Fluid TypeOperation TypeValve MaterialOverride FunctionalityWire Mesh Screen IncludedMounting TypeCoil TypeLeak RateInput VoltageResponse TimeCoil Nut Tightening TorqueFree Reverse FlowAdjustment Mechanism
DSH081NRE
Backordered
Backordered
$101.79/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °F30 L/min30 L/minC08-25000 psiD-Ring (Standard)0.25 lb43-49 NmNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush Type w/Extended RodNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH081NRES
Backordered
Backordered
$107.88/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualYesn/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °C30 L/min8 Gal/minC08-25000 psiD-Ring (Standard)0.11 kg32-36 lb-ftNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush Type w/Extended RodYesScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmYesN/A
DSH081NRM
Backordered
Backordered
$101.79/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C30 L/min8 Gal/minC08-2350 barD-Ring (Standard)0.11 kg32-36 lb-ftNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush Type w/Flush RodNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH081NRT
Backordered
24 in stock
$181.69/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °C8 Gal/min8 Gal/minC08-2350 barD-Ring (Standard)0.11 kg43-49 NmNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH081NRTV
Backordered
Backordered
$135.07/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C8 Gal/min30 L/minC08-2350 barFluorocarbon0.25 lb43-49 NmNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH081NRV
Backordered
Backordered
$94.83/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C8 Gal/min8 Gal/minC08-25000 psiFluorocarbon0.11 kg43-49 NmNormally OpenElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmYesN/A
DSH081NT
Backordered
Backordered
$122.02/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °C8 Gal/min8 Gal/minC08-2350 barD-Ring (Standard)0.25 lb43-49 NmNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftNoN/A
DSH081NTS
Backordered
Backordered
$134.63/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualYesn/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °F30 L/min30 L/minC08-25000 psiD-Ring (Standard)0.25 lb32-36 lb-ftNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistYesScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A
DSH081NTV
Backordered
Backordered
$133.11/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C8 Gal/min8 Gal/minC08-2350 barFluorocarbon0.11 kg43-49 NmNormally OpenElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A
DSH081NV
Backordered
Backordered
$92.00/each
EANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way+400 °F30 L/min30 L/minC08-25000 psiFluorocarbon0.25 lb32-36 lb-ftNormally OpenElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftNoN/A
DSH101C
3 in stock
7 in stock
$63.08/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °F60 L/min60 L/minC10-25000 psiD-Ring (Standard)0.41 lb51-55 lb-ftNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms7-10 NmNoN/A
DSH101CH
Backordered
Backordered
$101.79/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °C15 Gal/min60 L/minC10-2350 barD-Ring (Standard)0.2 kg51-55 lb-ftNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A
DSH101CHR
Backordered
Backordered
$101.79/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C15 Gal/min15 Gal/minC10-2350 barD-Ring (Standard)0.2 kg69-75 NmNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmYesN/A
DSH101CHRT
Backordered
Backordered
$142.68/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C15 Gal/min15 Gal/minC10-2350 barD-Ring (Standard)0.2 kg69-75 NmNormally ClosedElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmYesN/A
DSH101CHRTV
Backordered
Backordered
$146.38/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C15 Gal/min15 Gal/minC10-2350 barFluorocarbon0.41 lb69-75 NmNormally ClosedElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH101CHRV
Backordered
Backordered
$106.58/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+400 °F60 L/min15 Gal/minC10-25000 psiFluorocarbon0.2 kg69-75 NmNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A
DSH101CHT
Backordered
Backordered
$142.68/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C15 Gal/min15 Gal/minC10-2350 barD-Ring (Standard)0.2 kg51-55 lb-ftNormally ClosedElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A
DSH101CHV
Backordered
Backordered
$106.58/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way+400 °F60 L/min60 L/minC10-25000 psiFluorocarbon0.2 kg69-75 NmNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A
DSH101CR
12 in stock
47 in stock
$68.95/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNon/a350 barSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C15 Gal/min15 Gal/minC10-2350 barD-Ring (Standard)0.41 lb51-55 lb-ftNormally ClosedElectricalISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steeln/aNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms7-10 NmYesN/A
DSH101CRT
Backordered
30 in stock
$150.73/each
EANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNon/a5000 psiSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °C60 L/min15 Gal/minC10-2350 barD-Ring (Standard)0.2 kg69-75 NmNormally ClosedElectrical, ManualISO 4406 18/16/13, SAE Class 4Mineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelPush and TwistNoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms5-7 lb-ftYesN/A