Direct Acting Sequence Valve - B04J4GZNS

Parker’s direct acting sequence valves can be piloted and vented allowing multiple actuators to work in sequence based on pressure settings; working with flows up to 56 lpm (15 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Backordered
SKU B04J4GZNS
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileAdjustment MechanismScrew
Maximum Inlet Pressure Rating6000 PSI, 420 BARPressure Control Range30-2400 PSI, 2-166 BAR
Sealed Pilot IncludedYesFlow Rate12 GAL/MIN, 47 L/MIN
Seal MaterialNitrileMaximum Operating Temperature250 °F
Body Materialn/aMaximum Operating Pressure6000 psi
For Fluid TypeMineral-based Hydraulic FluidsConfigurationNormally Closed (NC)
Pilot LocationExternalValve MaterialSteel (all parts)
Filter Efficiency RatingISO 4406 18/16/13Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-34 °CMounting TypeScrew-in Cartridge
Actuation TypePressure SensingDivisionMobile Hydraulic Systems Division Europe
Operation TypeAutomaticAdjustment MechanismScrew
Maximum Tank Pressure6000 psiOperating Temperature-34 to 121 °C
Maximum Inlet Pressure Rating6000 psiLeak Rate25 cm3/min @ 1450 Psi (100 bar)
Installation Torque50 NmFunctionDirect Acting Sequence
Drain OptionExternalPressure Control Range2 to 166 bar
Maximum Pressure Setting166 barStandard Setting Pressure1160 psi
Pressure Control Sensitivity248 psi Per TurnSealed Pilot IncludedYes
Weight0.73 lbFlow Rate47 L/min
Cavity SizeC10-4Maximum Flow Rate47 L/min