Pilot Operated Sequence Valve with Kickdown - B04C3HZV

REGIONAL - Parker’s kick-down pilot operated sequence valve is a hydraulic fuse used to unload flow once the pressure setting is reached, resets when all flow is removed. Capable of flows up to 160 lpm (42 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Backordered
SKU B04C3HZV
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialFluorocarbonAdjustment MechanismScrew
Pressure Control Range145-3000 PSI, 10-210 BARFlow Rate42 GAL/MIN, 160 L/MIN
Maximum Operating Temperature400Seal MaterialFluorocarbon
Body Materialn/aFlow Rate42
DivisionHydraulic Valve Systems DivisionFor Fluid TypeSynthetic Hydraulic Fluids
Operating Temperature-15 to 400Cavity SizeC10-3S
Pilot LocationInternalValve MaterialSteel (all parts)
Filter Efficiency RatingSAE Class 4Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-15Maximum Operating Pressure6000
Weight0.55Mounting TypeScrew-in Cartridge
Actuation TypePressure SensingMaximum Pressure Setting3000
DivisionMobile Hydraulic Systems Division EuropeOperation TypeAutomatic
Adjustment MechanismScrewMaximum Tank Pressure6000
Pressure Control Range145 to 3000Pressure Control Sensitivity435 psi Per Turn
Maximum Inlet Pressure Rating6000Leak Rate100 cm3/min @ 1450 Psi (100 bar)
ConfigurationKick DownMaximum Flow Rate42
Installation Torque37Standard Setting Pressure1450
FunctionPilot Operated SequenceDrain OptionExternal
Product resources