Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Backordered
SKU SVH081S10N
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Rated Flow (gpm)12Cracking Pressure (psi)N/A
Pressure Range Adjustment (psi)100-1000Seal MaterialNitrile
Port Sizen/aBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-30 °FActuation TypePressure Sensing
Adjustment MechanismScrewMaximum Tank Pressure350 bar
Cavity SizeC08-3Weight0.25 lb
FunctionPilot Operated SequenceDrain OptionExternal
Flow Rate45 L/minMaximum Flow Rate45 L/min
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating380 bar
Installation Torque43-49 NmMaximum Operating Temperature+121 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-34 to +121 °C
Maximum Operating Pressure380 barMaximum Pressure Setting69 bar
Standard Setting Pressure34.5 barPressure Control Range6.9-69 bar
Maximum Drain Flow Rate0.15 Gal/minPressure Control Sensitivity285 per turn psi
Leak Rate82 @ 3000 PSI (210 BAR) cm3/minReseat Pressure90% of set pressure
Cracking PressureN/A bar