Pilot Operated Sequence Valves - SVH081T10

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Backordered
SKU SVH081T10
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialD-Ring (Standard)Pilot OptionInternal
Drain OptionExternalAdjustment TypeTamper Resistant
Rated Flow (gpm)12Cracking Pressure (psi)N/A
Pressure Range Adjustment (psi)100-1000Minimum Operating Temperature-35
Port Sizen/aBody Materialn/a
DivisionHydraulic Valve Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Weight0.25Maximum Operating Pressure5500
Actuation TypePressure SensingAdjustment MechanismTamper Resistant
Maximum Tank Pressure5000Cracking Pressuren/a
Seal MaterialD-Ring (Standard)Cavity SizeC08-3
FunctionPilot Operated SequenceDrain OptionExternal
Flow Rate12Maximum Flow Rate12
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating5500
Maximum Operating Temperature+200Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-35 to +200Installation Torque32-36
Maximum Pressure Setting1000Standard Setting Pressure500
Pressure Control Range100-1000Maximum Drain Flow Rate0.15
Pressure Control Sensitivity285 per turnLeak Rate82 @ 3000 PSI (210 BAR)
Reseat Pressure90% of set pressure