Pilot Operated Sequence Valves - SVH161S20

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Backordered
SKU SVH161S20
POR
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Cracking Pressure (psi)N/ARated Flow (gpm)40
Pressure Range Adjustment (psi)200-2000Seal MaterialNitrile
Port Sizen/aBody Materialn/a
Maximum Operating Pressure5500 psiDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationInternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-34 °C
Actuation TypePressure SensingAdjustment MechanismScrew
Maximum Tank Pressure5000 psiWeight1 lb
FunctionPilot Operated SequenceDrain OptionExternal
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating5500 psi
Installation Torque73 lb-ftFlow Rate40 Gal/min
Maximum Operating Temperature+121 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-34 to +121 °CStandard Setting Pressure69 bar
Maximum Pressure Setting2000 psiPressure Control Range200-2000 psi
Pressure Control Sensitivity37 per turn barLeak Rate5 per 100 psi (6.8 bar) setting cm3/min
Cracking PressureN/A barCavity Size6-3
Reseat Pressure80% of set pressureMaximum Flow Rate151.6 L/min
Maximum Drain Flow Rate0.5 L/min