Attribute nameAttribute value
Flow Rate8 GAL/MIN, 30 L/MINSeal MaterialD-Ring (Standard)
Adjustment MechanismFixedPressure Control Range200-3000 PSI, 13.8-210 BAR
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-35 °FMaximum Operating Temperature+200 °F
Maximum Operating Pressure350 barMaximum Flow Rate30 L/min
Actuation TypePressure SensingMaximum Pressure Setting210 bar
Weight0.11 kgOperation TypeAutomatic
FunctionPilot OperatedFlow Rate8 Gal/min
Maximum Tank Pressure5000 psiSeal MaterialD-Ring (Standard)
Cavity SizeC08-3Adjustment MechanismFixed
Maximum Inlet Pressure Rating380 barInstallation Torque43-49 Nm
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4For Fluid TypeMineral-based or synthetic hydraulic fluids
Mounting TypeScrew in cartridge valveOperating Temperature-35 to +200 °F
Pressure Control SensitivityN/A psiValve MaterialAll parts steel. All operating parts hardened steel.
Standard Setting Pressure1500 psiConfigurationPressure Reducing
Pressure Control Range200-3000 psiMaximum Drain Flow Rate0.15 Gal/min
Product resources